Rainwater Storage Tanks7 min read
How a Rainwater Harvesting System Works: Components, Storage and Uses
From roof to tank to tap: how the catchment, first-flush diverter, storage tank, pump and distribution work together in a rainwater harvesting system, and how to look after it.
By Fiber Teknik Mühendislik Ekibi

On this page
A rainwater harvesting system collects rain falling on a surface such as a roof through gutters and pipes, passes it through a first-flush diverter and filter, stores it in a light-tight tank and then pumps it to non-potable uses such as irrigation, toilet flushing, process or cooling water. It has five links: catchment, pre-treatment, storage, pump and distribution, and overflow. Water quality depends far more on getting those links right than on the size of the tank.
Below we go through each link in turn, along with the mistakes we see most often.
Why install one?
Rainwater harvesting cuts demand on mains water and relieves the load on sewers and storm drains during heavy rain. In Turkey, the Planned Areas Zoning Regulation makes rainwater harvesting mandatory on plots larger than 2,000 m². A system also contributes to water-efficiency targets under green building schemes such as LEED, BREEAM and YeS-TR.
Five links: components and what they do
1. Catchment
The roof is the most productive catchment. How much of the rain that falls on it actually reaches the tank is expressed by a runoff coefficient that depends on the roof finish. Gutters and downpipes should have leaf guards, and where possible all downpipes should join a single collection line. Water from surfaces with vehicle traffic, such as car parks and roads, can carry oil and particles and needs to be assessed separately.
2. First flush and filtration
In the first minutes of a rainfall, dust, pollen and bird droppings on the roof wash into the water. A first-flush diverter separates that dirty first portion and lets the cleaner water continue to the tank. A filter after it catches coarse debris. Most of the quality of the stored water is decided at this stage: sediment that gets into the tank becomes a bottom layer that is hard to remove later.
3. Storage tank
The tank has two basic jobs: hold the water without leaking and keep it out of the light. Light starts photosynthesis and algae grows, so the shell must be opaque. Our GRP rainwater tanks are made from opaque Isophthalic GRP that withstands acidic rainwater, and tanks for above-ground service get a UV-resistant top-coat.
Inside the tank, two details protect water quality:
- Calmed inlet: incoming water does not hit the floor and stir up settled sediment.
- Sediment-protected outlet: the draw-off point sits 10–15 cm above the floor.
Choice of material: in a concrete cistern, leak-tightness depends on workmanship and on cracks that develop over time. A monobloc GRP shell has no joints, so that risk disappears, and the shell does not corrode. For small above-ground systems a polyethylene water tank is also a practical option; outdoors, choose a UV-blue body that blocks sunlight. For large volumes and buried tanks, GRP is the material to use.
Above ground or underground? An above-ground tank is easier to install and inspect. An underground tank frees the land above it and stays dark naturally. Bedding, backfill and burial depth for underground tanks are a subject of their own; we cover them in detail in our guide to underground GRP tanks.
4. Pump and distribution
Stored water is usually delivered by a booster set or a submersible pump. Following the sediment-protected outlet principle, the pump should draw from a little above the floor, not from the bottom itself. The rainwater distribution network should be physically separate from the drinking water supply, with pipes and taps labelled "not drinking water". If the system is topped up from the mains when the tank runs dry, an air gap or backflow preventer is needed so mains water cannot be contaminated by the rainwater line. That is a general plumbing engineering rule, and the details should be worked out with your designer.
5. Overflow
When the tank is full, excess water leaves through the overflow. The overflow pipe should be the same diameter as the inlet or larger, with a check valve to keep vermin and odours out. Overflow water goes to the storm drain or a soakaway.
Where the water is used
- Landscape and garden irrigation: the most common and simplest use.
- Toilet flushing: in buildings this can cover a meaningful share of mains consumption.
- Process and cooling water: industrial uses that do not need drinking-water quality.
- Washing and cleaning: yards, vehicles and equipment.
Harvested rainwater should not be used as drinking water without further treatment.
A short note on capacity
The annual harvestable volume is Vy = (A × Y × e) / 1000, where A is the roof area (m²), Y the annual rainfall (mm) and e the runoff coefficient. Tank size, however, comes from your demand through the longest dry spell, not from that annual figure. For the full calculation and a worked example, see the underground tanks article linked above. Our GRP rainwater tanks are made from 2,000 to 250,000 L, for operating temperatures from -20°C to +60°C.
Maintenance checklist
To keep the system running for years, do the following regularly:
- Clean the leaf guards on gutters and downpipes, especially in autumn.
- Empty and clean the first-flush diverter and the filter; check them after periods of heavy rain.
- Check the depth of sediment on the tank floor from time to time; drain the tank and remove it when needed.
- Confirm that the pump intake and its non-return valve are working.
- Check that the overflow is clear and that its check valve keeps vermin out.
- Make sure manhole covers are closed and sound.
- Check that the "not drinking water" labels on the distribution network are still in place.
Because a GRP shell does not corrode, the tank itself needs almost no maintenance, and its design life is 50+ years. Most of the maintenance effort sits with the pre-treatment components in front of the tank.
How Fiber Teknik helps
Tell us your roof area, what the water is for and whether you want the tank above or below ground, and we will work out the volume, the shell type and the calmed inlet, sediment-protected outlet and overflow fittings with you. You can read more on our rainwater storage tanks page, or our polyethylene water tanks for small above-ground systems, and use the quote button whenever you are ready.