Rainwater Storage Tanks7 min read
Choosing a Polyethylene Water Tank: Vertical or Horizontal? Capacity, Dimensions and Placement
Choosing between standard vertical, narrow (slimline) and horizontal polyethylene water tanks: how to read the dimension table, fit through doors and under ceilings, prepare the base, and when to move to GRP.
By Fiber Teknik Mühendislik Ekibi

On this page
Choose a vertical tank if you have height to spare and little floor area, and a horizontal tank if the ceiling is low or the tank will travel on a vehicle. If the tank has to go through a narrow door into a basement or boiler room, look at the narrow (slimline) vertical models. The decision is driven not by litres but by three measurements: body diameter, overall height and the narrowest point on the route the tank has to take.
Fiber Teknik polyethylene water tanks come in 27 standard models from 100 L to 20,000 L: 13 standard vertical, 3 narrow (slimline) and 11 horizontal.
Three body types
- Standard vertical (300–20,000 L): the most widely used series for homes, residential complexes, irrigation, fire reserves and process water. It fits the most volume onto a given floor area.
- Narrow, or slimline (500, 750 and 1,000 L): the same volume in a smaller diameter and a taller body, designed to be carried through doorways and tight passages.
- Horizontal (100–5,000 L): a low centre of gravity and moulded feet make it suitable for low-ceilinged rooms, truck and trailer transport, mobile spraying and construction sites.
How to read the dimension table
The tables on our product pages give the following for each model:
- Diameter: the widest outside dimension of the body. This is what decides whether it fits through a door.
- Height: overall height including the lid. This decides whether it fits under the ceiling, and whether it fits through a door when tipped on its side.
- Mouth diameter: the diameter of the top opening, which is your access for cleaning and inspection.
- Outlet: the size of the ready-fitted connector; it has to match your pipework.
- Weight: the empty weight, which matters for handling and placing the tank by hand.
Representative models from the vertical series (dimensions in cm):
Representative models from the horizontal series (dimensions in cm):
Two things stand out. First, the same 1,000 litres comes in three shapes: a standard vertical tank 101 cm across and 141 cm tall, a narrow tank 75.5 cm across and 199 cm tall, and a horizontal tank 88 cm tall. Second, outlet size grows with capacity; from 5,000 litres up, a Ø63 mm (2") outlet is standard.
How much capacity?
A rule of thumb for a first estimate: multiply your daily water use by the number of days the tank has to cover. If the tank is a reserve against mains interruptions, base the days on the longest outage you expect; for irrigation, on the interval between waterings. Round up to the next standard size. If the result will not fit the dimensions of a single tank, two smaller tanks connected together are often easier to get through the door and place.
Getting it through the door and under the ceiling
Measure the route before you order:
- Measure the narrowest clear width along doors, corridors and stairs, allowing for the frame and the door leaf.
- Compare that width with the tank diameter. As a rule of thumb, leave a few centimetres over the diameter for carrying and manoeuvring.
- If the diameter will not fit, look at the narrow model of the same capacity. At 1,000 litres, for example, the diameter drops from 101 cm to 75.5 cm.
- If you plan to tip the tank on its side to get it through, remember that its height then has to fit the door width too.
- At the final position, measure the ceiling height and leave room above the tank to open the lid and look inside.
- If the ceiling does not allow that, switch to the horizontal model of the same capacity.
Preparing the base
A full tank's load is mostly the water, not the tank: a litre of water weighs about 1 kg, so a full 10,000-litre tank puts roughly 10 tonnes on the floor on top of its own 190 kg.
- Set the tank on a flat, level surface that supports the whole base; a concrete slab or compacted, levelled ground is suitable.
- Leave no sharp stones, edges or voids under the base; point loads can damage the shell.
- For roof and terrace installations, have a structural engineer confirm the slab can carry the full tank.
- Connect the outlet and valve to the pipework with a flexible joint, so the pipework does not load the tank wall.
Food contact and UV
Our tanks are rotationally moulded as one weld-free piece from food-contact linear polyethylene that conforms to FDA 21 CFR 177.1520. The double-layer, UV-stabilised wall blocks sunlight to prevent algae, and imparts no odour, taste or colour to the water between -5°C and +65°C.
Choose the colour for where the tank will stand. UV blue blocks sunlight outdoors and on roofs; natural food-white lets you see the water level from outside in indoor plant rooms.
When to move to GRP
A polyethylene tank is not the right tool when you need:
- More than 20,000 litres in one tank: GRP tanks are made up to 250,000 litres.
- A buried tank: our externally ribbed underground GRP tanks are designed for soil load and lateral pressure.
- Temperatures above +65°C or chemical content: you need a GRP tank with a resin matched to the liquid.
- A long-term infrastructure asset: GRP tanks have a 50+ year design life; polyethylene's service life is shorter.
How Fiber Teknik helps
Tell us the volume you need, the door and ceiling dimensions at the installation site and what the water is for, and we will choose the right model with you. Dimension tables for every model are on our polyethylene water tanks page; for larger volumes and buried installations see our rainwater storage tanks, and use the quote button whenever you are ready.