Skip to main content
Fiber Teknik
Septic Tanks

GRP.04GRP composite

Septic Tanks

TS EN 976-1 externally ribbed underground GRP septic reactors, 100% pressure-tested for soil overburden, vacuum pump-out, and biogenic H₂S immunity.

2,000 – 150,000 L
Capacity
-20°C … +60°C
Operating temperature
50+ years
Design life
TS EN 976-1
Standard

Specifications

The datasheet at a glance.

Capacity, temperature, resin system and standards on one page.

Choose “Save as PDF” in the print dialog.

Operating envelope

Capacity
2,000 – 150,000 L
Operating temperature
-20°C … +60°C
Design life
50+ Years Underground Life
Series code
GRP.04

Construction

Manufacturing process
Ribbed Monobloc Filament Winding + Factory Hydro/Pneumatic Leak Test
Material system
Biogenic Sulfuric Acid (H₂S) Immune Isophthalic GRP Composite (8–12 mm+)
Geometries
Horizontal Cylindrical UndergroundAnti-Implosion BaffledManhole Risers

Standards and compliance

  • TS EN 976-1
  • EN 976-1 Underground
  • ISO 9001:2015

Fiber Teknik GRP Underground Septic Tanks are 100% leak-tested monobloc vessels engineered per TS EN 976-1 with external structural ribs, anti-implosion vacuum baffles, and full immunity to biogenic H₂S sulfuric acid corrosion.

Configured to order

Every vessel is engineered for your process. Five facts are enough for our engineers to specify the right resin, wall thickness and connections.

Select capacity

  1. 01

    Stored medium

    Name of the fluid or product, concentration and pH

  2. 02

    Capacity

    Net volume, flow rate or daily consumption

  3. 03

    Temperature

    Normal and maximum operating temperature

  4. 04

    Installation

    Aboveground, underground or vehicle-mounted; site and crane access

  5. 05

    Connections

    Flanges, manholes, level indication and equipment nozzles

Overview

TS EN 976-1 compliant, fully leak-proof septic tanks for rural areas, construction sites and temporary settlements unreached by central sewage infrastructure. Previously common 'leaking' (cesspit) systems are prohibited under Water Pollution Control Regulation.

Our GRP tanks are not simple storage units but passive treatment reactors where anaerobic bacterial processes occur.

Traditional reinforced concrete septic tanks deteriorate structurally as sulfates in wastewater convert to biogenic sulfuric acid. Our GRP tanks provide full resistance to underground corrosion, tree root penetration and wastewater chemicals.

Septic Tanks
Geotechnical Design and Environmental Protection

Technical Advantages

Engineering specifications and structural advantages

  1. 100%

    01

    100% Leak-Proof Guarantee

    Monobloc body, factory-verified leak-tightness with water/air pressure test, zero environmental penalty risk.

  2. 02

    Biogenic Corrosion Resistance

    Full immunity to sulfuric acid formed by H₂S and methane gases, doesn't deteriorate like concrete.

  3. 8–10 mm

    03

    Ribbed Structure

    8-10 mm wall thickness with external ribs providing resistance to soil load, lateral pressure and vehicle traffic.

  4. 10+ ton

    04

    Baffle Partitions

    Implosion protection against sudden vacuum effect during pump-out in 10+ ton tanks.

Anaerobic Treatment Reactor Technology

Wall section

A four-layer composite wall.

From the wet face to the UV shield, each layer has its own duty; total wall thickness follows the static design.

Four-layer cross-section of a CNC filament-wound GRP vessel wallFrom the wet face outward: 01 gelcoat and C-glass veil (0.3–0.5 mm), 02 isophthalic / vinyl ester corrosion barrier (2.0–3.5 mm), 03 CNC ±55° / 90° wound structural E-glass core (5.0–22.0 mm), 04 UV-stabilised topcoat (0.3 mm).Stored medium · wet faceExterior · UV±55° helical / 90° hoop01020304Total wall thickness7.6 – 26.3 mm

Design and installation rules

  1. 15–20 cm

    01

    Proper Ground Preparation

    Long service life with 15-20 cm lean concrete bed and stone/debris-free pea gravel (3/8 inch) backfill.

  2. 02

    Burial Depth Flexibility

    Standard 30 cm, optional 50+ cm burial depth with special wall thickness increase.

  3. 150–300 L

    03

    Capacity Calculation

    Optimum volume based on 150-300 L/day wastewater production per person, household size and pump-out frequency.

  4. 15 meter

    04

    Placement Rule

    Minimum 15 meter distance requirement from septic tanks and pollution sources.

Technical FAQ

Technical questions, answered

Hydrogen sulfide (H₂S) gas oxidizes into biogenic sulfuric acid that cracks concrete and contaminates groundwater; monobloc GRP is chemically immune, root-proof, and installs via crane in hours rather than weeks.

Get Free Quote

Get a Free Quote for Your Project

We're ready to listen to your needs and offer custom solutions. Our expert engineers will contact you as soon as possible.

WhatsApp
+90 (533) 594 68 50