Technology6 min read
8 Questions Before Ordering a Polyester (GRP) Tank: Capacity, Medium, Temperature, Siting
The eight questions a manufacturer needs answered to design the right tank, and why each one matters: medium, temperature, capacity, siting, geometry, connections, site access and standards.
By Fiber Teknik Mühendislik Ekibi

On this page
- Why so many questions?
- 1. What will you store, and at what concentration?
- 2. What temperature?
- 3. How many litres, at what density?
- 4. Above ground or below?
- 5. What geometry?
- 6. Which connections and fittings?
- 7. What is site access like?
- 8. Which standards and documents?
- Summary table
- Comparing the quotes you receive
- Pre-quote checklist
- How Fiber Teknik helps
The short answer: to design a polyester (GRP) tank properly, the manufacturer needs eight pieces of information: the medium and its concentration, temperature, capacity, whether the tank sits above or below ground, geometry, connections, site access, and the standards to follow. These answers directly set the resin, the wall thickness and the shape of the shell. A quote based on missing information means a tank that is either more expensive or weaker than it needs to be.
Below we go through each question and why it is asked.
Why so many questions?
A GRP tank is not picked off a shelf; it is a calculated structure. The wall has four layers from the inside out: the gelcoat and C-glass veil in contact with the liquid, the corrosion barrier, the structural E-glass wound at ±55° and 90°, and a UV-protected outer coat. The first two are chosen for the liquid, the structural wall for the load, and the outer coat for the environment. The questions below feed those three choices.
1. What will you store, and at what concentration?
This decides the resin. Orthophthalic resin may be enough for simple water storage; isophthalic is used for drinking water and moderate chemical duty; vinyl ester for acids, alkalis, solvents and oxidisers. Food contact needs a food-grade resin and gelcoat. Since different concentrations of the same chemical can need different resins, give the percentage and any other components of the mixture along with the chemical's name.
2. What temperature?
Resin resistance falls as temperature rises. Our chemical tanks go up to 90–110°C depending on resin type, while our food tanks are rated for -25°C to +85°C. Give the highest value as well as the normal operating temperature: the peak of an exothermic reaction, hot washing, or the risk of freezing in winter.
3. How many litres, at what density?
Capacity sets the dimensions; density sets the structural load. Water and a dense chemical in the same volume put different loads on the shell, and the design follows that load. State the net (usable) capacity and any freeboard you need. Fiber Teknik builds filament-wound tanks from 1,000 to 250,000 litres.
4. Above ground or below?
Above ground, wind, sunlight (UV) and outside temperature matter. Below ground, soil pressure and groundwater decide the design, and these tanks are built with an externally ribbed shell; our underground olive tanks, for example, are designed for 3.5–4 m of soil load. Tell us the burial depth, whether vehicles will pass over the tank, and the groundwater level. Where groundwater is high, an empty tank has to be anchored against buoyancy; as a general engineering rule, that belongs in the installation plan from the start.
5. What geometry?
Vertical, horizontal or rectangular; flat, conical or sloped bottom. A vertical tank takes little floor area; a horizontal tank suits low ceilings and underground installation. If you need full drainage, choose a conical or sloped bottom; on silos that cone is 45°–65°. Give any diameter or height limits on site.
6. Which connections and fittings?
Fill and draw-off nozzles, overflow, vent, manway, level gauge, safety valve, mixer, heating coil or jacket, sensor ports. Every connection means a reinforced zone in the shell, so it belongs in the design rather than being added later. If there is a mixer, the flange area is strengthened for the motor's vibration and torque.
7. What is site access like?
If the tank is made in the factory and travels by road, its diameter has to fit road and bridge clearances. A crane has to reach the installation point, and doors and passages must be wide enough. For tanks too large to transport, Fiber Teknik can bring its production equipment to your site and build the tank there. The site address, the access route and photos of the installation area speed up this decision. It also helps to settle the base the tank will stand on (concrete plinth, steel structure or sand bed) in advance; the bottom is designed for that base, and installation day brings no surprises.
8. Which standards and documents?
Chemical tanks reference EN 13121-3, BS 4994 or ASTM D3299; food tanks reference FDA 21 CFR 177.2420, TSE 266 and EN 13121. If your site is subject to specific regulation (for example a double-wall or bund requirement for hazardous chemicals), say so at the start so the design accounts for it.
Summary table
Comparing the quotes you receive
When you collect quotes from several manufacturers, comparing price per litre is not enough. If the quotes do not describe the same tank, the prices are not comparable either. Look for these points in each one:
- Is the resin named? "Chemical resistant" is not enough; the quote should say which resin (isophthalic, vinyl ester, novolac vinyl ester) goes into the corrosion barrier.
- Is a design standard cited? A code such as EN 13121, BS 4994 or ASTM D3299 shows what the wall calculation is based on.
- Is the wall build-up described? Inner layers, structural wall and outer coat should each be defined.
- Does the nozzle list match yours? A missing connection means cutting into the shell on site.
- Is the scope clear? Are transport, crane, installation and, if needed, on-site production included or excluded?
Choosing the lowest price before these points are settled often means choosing a tank that has not been fully specified.
Pre-quote checklist
- Name, concentration and density of the medium.
- Normal and maximum temperature.
- Net capacity.
- Above or below ground; if below, depth and traffic load.
- Shape, bottom type and size limits.
- Nozzle and fittings list.
- Site address and access details.
- Standard to follow and documents required.
How Fiber Teknik helps
You do not need every answer before you call; our engineers can work through the open points with you. For the material and the production method see our technology page, and for specific applications our chemical tanks and food tanks pages. Once the list is filled in, send it to us with the quote button on this page.